Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Res. Biomed. Eng. (Online) ; 33(1): 1-10, Mar. 2017. tab, graf
Article in English | LILACS | ID: biblio-842485

ABSTRACT

Abstract Introduction Numerical phantoms are important tools to design, calibrate and evaluate several methods in various image-processing applications, such as echocardiography and mammography. We present a framework for creating ultrasound numerical deformable phantoms based on Finite Element Method (FEM), Linear Isomorphism and Field II. The proposed method considers that the scatterers map is a property of the tissue; therefore, the scatterers should move according to the tissue strain. Methods First, a volume representing the target tissue is loaded. Second, parameter values, such as Young’s Modulus, scatterers density, attenuation and scattering amplitudes are inserted for each different regions of the phantom. Then, other parameters related to the ultrasound equipment, such as ultrasound frequency and number of transducer elements, are also defined in order to perform the ultrasound acquisition using Field II. Third, the size and position of the transducer and the pressures that are applied against the tissue are defined. Subsequently, FEM is executed and deformation is computed. Next, 3D linear isomorphism is performed to displace the scatterers according to the deformation. Finally, Field II is carried out to generate the non-deformed and deformed ultrasound data. Results The framework is evaluated by comparing strain values obtained the numerical simulation and from the physical phantom from CIRS. The mean difference between both phantoms is lesser than 10%. Conclusion The acoustic and deformation outcomes are similar to those obtained using a physical phantom. This framework led to a tool, which is available online and free of charges for educational and research purposes.

2.
Rev. bras. eng. biomed ; 30(2): 159-172, Apr.-June 2014. ilus, graf, tab
Article in English | LILACS | ID: lil-714731

ABSTRACT

INTRODUCTION: The rupture of atherosclerotic plaques causes millions of death yearly. It is known that the kind of predominant tissue is associated with its dangerousness. In addition, the mechanical properties of plaques have been proved to be a good parameter to characterize the type of tissue, important information for therapeutic decisions. METHODS: Therefore, we present an alternative and simple way to discriminate tissues. The procedure relies on computing an index, the ratio of the plaque area variation of a suspecting plaque, using images acquired with vessel and plaques, pre and post-deformation, under different intraluminal pressure. Numerical phantoms of coronary cross-sections with different morphological aspects, and simulated with a range of properties, were used for evaluation. RESULTS: The outcomes provided by this index and a widely used one were compared, so as to measure their correspondence. As a result, correlations up to 99%, a strong agreement with Bland-Altman and very similar histograms between the two indices, have shown a good level of equivalence between the methods. CONCLUSION: The results demonstrated that the proposed index discriminates highly lipidic from fibro-lipidic and calcified tissues in many situations, as good as the widely used index, yet the proposed method is much simpler to be computed.

SELECTION OF CITATIONS
SEARCH DETAIL